Product description
The Baclyser® neo T is a sterile1, point-of-use tap filter for use in high-risk areas
of medical facilities for the prevention of bacterial nosocomial infections caused by Pseudomonas aeruginosa, Legionella pneumophila, Stenotrophomonas maltophilia or Staphylococcus aureus in immunocompromised and immunosuppressed patients. The effect is achieved by interrupting the transmission path of these germs through filtration of the water and protection against retrograde contamination when using the water taps through hygienic design and antimicrobial protection functions. The Baclyser® neo T is available in three different service lifes (1M, 2M and 3M) and in two different outlet variants each (laminar and rose).
Technical data
Size: 49.3 mm x Ø 52 mm Retention: 7 log steps 2 Membrane: Flat sheet membrane, pore size 0.2 μm
Operating time: up to 31, 62 or 93 days (1M, 2M or 3M) 3
Flow rate: 15.5 l/min at 5 bar,
13.1 l/min at 3 barMax. operating pressure: 5 bar 4
Max. operating temperature: 60 °C
(at 75 °C ≤ 90 min over operating time) Connection: Quick-release coupling Chlorine resistance: ≤ 10 ppm 5 Chlorine dioxide resistance: ≤ 0,8 mg/l
Maintenance and Cleaning
The Baclyser® neo T requires no maintenance within the specified operating time. The outside of the filter can be cleaned using common surface disinfectants. To prevent retrograde contamination, daily wipe disinfection of the Baclyser® neo T is recommended.
When replacing the Baclyser® neo T, a small amount of unfiltered water will flow out. Over time, this will lead to deposits. For this reason, adapters and connections should be checked at regular intervals for functionality and proper condition and replaced as required.
top of page
SKU: 102692
£28.00Price
Excluding VAT
Price Options
One-time purchase
£28.00
Repeat order 1 month
Subscribe and save 5%
£26.60every month until canceled